The existence of this guide may be able to troubleshoot error on copy of canon which usually make the customer was less comfortable. I hope your machine may be able to work well and always in condition. Thank you.
* Caution:
in some cases the error is happening inside the engine needs a reset in service mode, to enter into the program, the following are the steps:
Please press the button additional fungtion is in the monitor panel.
Press a number two and eight simultaneously
Press the back button additional fungtion and follow the instructions on the error code you were provided.
Canon IR Series |
Canon imageRUNNER Series
Canon imageRUNNER C3200canon imageRUNNER 2530
Canon imageRUNNER 1310
Canon imageRUNNER 1630
Canon imageRUNNER 1670F
Canon imageRUNNER 2016
canon imageRUNNER 1133
Canon imageRUNNER 2230
Canon imageRUNNER 2270
Canon imageRUNNER C2570
Canon imageRUNNER 2830
Canon imageRUNNER 2870
Canon imageRUNNER 3320
Canon imageRUNNER 3530
Canon imageRUNNER 3570
Canon imageRUNNER C3170U
Canon imageRUNNER C3170i
Canon imageRUNNER 4270
Canon imageRUNNER 4570
Canon imageRUNNER C4580
Canon imageRUNNER C4580i
Canon imageRUNNER 5070
Canon imageRUNNER 5570
Canon imageRUNNER 6570
Canon imageRUNNER C5870
Canon imageRUNNER C6870
Canon imageRUNNER 7086
Canon imageRUNNER 7095
Canon imageRUNNER 7105
Canon imageRUNNER 8070
Canon imageRUNNER 110
Canon imageRUNNER 150vp
Canon imageRUNNER 2022N
Canon imageRUNNER Advance c5035
Canon imageRUNNER Advance c5045
Canon imageRUNNER Advance c5025
Canon imageRUNNER Advance c5030
Canon imageRUNNER Advance c7055
Canon imageRUNNER Advance c7065
Canon imageRUNNER Advance c9065
Canon imageRUNNER Advance c9075
Error Code Canon IR
E000
The main cause: the main thermistor (TH1) has poor contact or an open thermal switch circuit. The (TP1) has a heater circuit. The open repair has a circuit. Open the RSKfaulty. The DC controller PCB faulty. Detection mode: 0000 after the main power switch is turned on, the temperature detected by the main thermistor does not reach 70 ºc.Attention: mistakes have to be reset in service mode (COPIER > > FUNCTION CLEARERR >)
E001
The main cause: the main thermistor (TH1) has a short sub thermistor circuit. The (TH2) has detected overheating. The RSK is faulty. The DC controller PCB faulty. Detection mode: 0001 The main or sub thermistor thermistor has detected approximately230 º C or higher for 2 sec. 0002 this main thermistor detected 230 º C or higher (detection circuit hard) 0003 this sub thermistor detects about 236 ° C or higher. Attention: mistakes have to be reset in service mode (COPIER > > FUNCTION CLEAR ERR>)E002
The main cause: the main thermistor (TH1) has poor contact or an open thermal switch circuit. The (TP1) have RSK circuit. Open the faulty. The DC controller PCB faulty.Detection mode: 0000 Temperature from the top fixing roller does not reach 100 °C within 2 minutes after it has exceeded 70 º c. caution: faults must be reset in service mode (COPIER > > FUNCTION CLEAR ERR >)E003
The main cause: the main thermistor (TH1) has poor contact or an open thermal switch circuit. The (TP1) has a heater circuit. The open repair has a circuit. Open the RSKfaulty. The DC controller PCB faulty. Mode of detection: 0000 main thermistor detected a temperature of 70 ° C for 2 seconds or more after it has reaced 100 º c. caution: faults must be reset in service mode (COPIER > > FUNCTION CLEAR ERR >)E004
The main cause: RSK has short-circuit. The DC Controller PCB faulty. Detection mode: 0000 The RSK is used to fix the heater drive found to have a short circuit (circuit detection hardware). Attention: mistakes have to be reset in service mode (COPIER >> FUNCTION CLEAR ERR >)E005
The main cause: fixing the Web had been taken. Web fix Length sensor (PS45) is faulty. The DC controller PCB faulty. Detection mode: 0000 Long fixing the web has taken is more than the specified length. Note: After replacing the web improve, be sure to reset the two web counter in service mode: COPIER COUNTER > > MISC > FIX-WEB and COPIER COUNTER > > DRBL-1 > FX-WEB.E010
The main cause: main motor (M2) is damaged. The DC Controller PCB faulty. Detection mode: the clock pulse is not 0000 arrived for 2 seconds or more after the main motor driving signal (MMFG) have been produced.E012
The main cause: the drum Motor (M1) is damaged. The DC Controller PCB faulty. Detection mode: The clock pulse is not 0000 arrived for 2 seconds or more after the signal the motor drives the drum (DMFG) have been produced.E013
The main cause: the waste toner feedscrew damaged. Waste toner sensor Clock (MSW2) damaged. The DC Controller PCB faulty. Detection mode: 0000 waste toner feedscrew from Rotation out of order, and the switch (MSW2) suppressed several times during a given period.E014
The main cause: Motor repair (M19) damaged. The DC Controller PCB faulty. Detection mode: 0000 The signals clock motor is detected for 2 seconds or more continuously after fixing the motor drive has produced.E020
The main cause: the connector hopper is left disconnected. Hopper motor(M9/M10) toner is faulty. The sensor (TS1/TS2) is damaged. The DC Controller PCB faulty. Detection mode: 0000 when printing, toner supply is ' 0 ' (the absence of toner) for 2 minutes.E032
The main cause: copy data controller or remote diagnostic device is damaged. The main controller PCB faulty. Detection mode: 0001 though so connected, copy data controlleror remote diagnostic devices have become disconnected.E061
The main cause: the laser shutter is broken. The laser unit is defective. Measurement of potential PCB damaged. The DC Controller PCB faulty. Detection mode: 0001 as a result of potential control, the potential of the surface of the drum (VL2) from a white background is about 200V(Produces a solid black image) 0.0002 main charging Output used to print output and potential output after the laser drum surface has been made about 200V (producing solid black image).
E100
The main cause: BD PCB is damaged. The laser unit is defective. Laser driver PCB isfaulty. Broken cable (short circuit, open circuit). The controllerPCB DC faulty. Detectionmode: 0001 In 100 msec after the signal has been generated laser hard, the signal is not detected BD is 50 times or morein 40 msecs. 0002 while the laser is active, the cycle signal BD found is beyond aspecific 10 times or more.
E110
The main causes: laser scanner motor (M15) is damaged. Broken cable (short circuit,open circuit). The DC Controller PCB faulty. Detection mode: 0001 • After laser scanner motor drive signal has been generated, the motor ready signal (LMRDY *) does not come to15 seconds or more. (Stop-full speed, half speed-full speed) • during the period of 'full speed ' half-speed, signal the motor that does not come ready for 60 seconds ormore after
change the speed signal has been generated. • During the period of ' rotation at full speed ", signals the motor ready not detected 50 times or more (t 100 msecinterval).
E121
The main cause: the cooling fan controller (FM4) is damaged. Broken cable (short circuit, open circuit). The DC Controller PCB faulty. Mode of Detection0001 Though the cooling fan controller (FM4) is being driven, the signals clock (FM4LCK) don't come for 5 seconds or more.Causes of E196Main: EEPROM on the DC controller PCB is damaged. The location ofthe EEPROM are wrong. The DC Controller PCB faulty. Detection mode: 1abb Whendata is written to the EEPROM, the data is written and read data do not match. 2abbWhen ID is read into the EEPROM and ROM ID into compared, discrepancies are found. 3abb when the ID in the ID in ROM and EEPROM than after the main power switch is turned on, a mismatch is found. a: No Chip 0 to 5 (0:1: IC104 IC105 IC109, 2:, 3:IC110, 4 : IC127, 5: IC130) address: bb damaged chips (bits)
E202
The main cause: the HP scanner sensor (PS39) damaged. The scanner motor (M3) is damaged. The reader controller PCB faulty. Detection mode: 0001 the scanner HP Sensor does not turn off even when the scanner has been moved forward 40 mm after the main power switch is turned on or the Start button has been pressed for. 0002 Scanner HP Sensor does not light up even when the scanner has moved 450 mm the code reverse. Caution is not indicated, and the button is locked. The code can be checked in the service mode (DISPLAY > > COPIER ERR).E204
The main cause: ADF PCB controller is damaged. The reader controller PCB faulty. Detection mode: 0001 when printing, the image of the leading edge of signal does not come from the ADF code. Caution is not indicated, and the button is locked. The code can be checked in the service mode (DISPLAY > > COPIER ERR).E220
The main cause: a lamp inverter PCB is damaged. The reader controller PCB faulty. Detection mode: 0001 Lamp inverter PCB were found to have errors.E225
The main cause: scanning Light (xenon tube) is damaged. Faulty inverter PCB.CCD/AP PCB damaged. The reader controller PCB faulty. Detection mode: 0000 A certain signal level can not be achieved by getting the correction of CCD on power-on. 0002 Advantage edge correction value changed more than a certain level as compared to the value of correction used for previous sheet.E240
The main cause: the controller to the main PCB. The DC Controller PCB faulty. Detection mode: 0000 an error has occured in the communication between the main controller PCB and the CPU from DC controller PCB.E243
The main cause: Control Panel CPU PCB damaged. The main controller PCB faulty. Detection mode: 0000 an error has occured in the communication between the control panel CPU CPU PCB and the main controller PCB.E248
The main cause: the EEPROM on the reader controller PCB is damaged. The reader controller PCB faulty. Detection mode: 0001 ID read into EEPROM when the main power switch is turned on and not in ROM ID match. 0002 When data is written to theEEPROM, the data is written and read data do not match. 0003 When data is written, the ID in the EEPROM and ROM ID found unsuitable.E302
The main cause: CCD/AP PCB damaged. Broken cable (short circuit, open circuit). The reader controller PCB faulty. Detection mode: 0001 For shading, the reader controller PCB did not end up shading within 1 sec. 0002 in the reading flow, accumulation of white edges (processing) do not expire after a period of 10 seconds.E601
The main cause: this cable is faulty (short circuit, open circuit). Hard disk drive is damaged. The DC Controller PCB is damaged. The main controller PCB faulty. Detection mode: 0000 main controller PCB has detected an error in the image was transmitted datawhile control between primary hard disk controller PCBand controller maindrive. 0001 PCB has found errors in control data image between governing PCB intransfer main and controllerPCB DC.E602
The main cause of the cable is faulty (short circuit, open circuit). The isfaulty hard drive disk. The main controller PCB faulty. Fashion ofDetection0001 A mountain error is detected when the hard disk starts the boot ROM. 0002 upfrom an error reading data (from the hard disk) was detected when the hard disk starting from the boot ROM.E607
The main cause of the fan hard disk (FM7) damaged. Cable damage (a shorthyphen, opencircuit). The DC Controller PCB faulty. OfDetection0000 mode While the fan hard disk (FM7) is being driven, the signals clock (FM7CLK) don't come for 5 seconds or more.
E677
The main cause of the Council the various printer (accessories) are broken. The maincontroller PCB faulty. Fashion ofDetection0001 an error has occured in the communication between the variousE710
The main causes of the DC controller PCB is damaged. The reader controller PCB faulty. The main controller PCB faulty. OfDetection0001 mode When the main power is turned on, the IPC (IC5021) on the PCB cannot be initialized readercontroller. 0002When the main power is turned on, the IPC (IC120) on PCB DCcontroller cannot be initialized. 0003 When main power is turned on, the IPC (IC1003) on the PCB maincontroller cannot be initialized.E711
The main cause of the connector is not connected properly. PCBis remote diagnostic device is damaged. PCB copies the data controller is damaged. ADF isfaulty controller PCB. ADF PCB controller is damaged. Finisher isfaulty controller PCB. Mode of 0001 Detection data has been written to the error register IPC (IC5021) onthe reader controller PCB four times or more within 1.5 secs. 0002 data has been written to the error register IPC (IC120) onthe DC controller PCB four times or more in 2 secs. 0003 data has been written to the error register IPC (IC1003) of the solar controller PCB main four or more times within 2 seconds.E712
The main cause of the connector is not connected properly. ADF 24-V isfaulty power supply. ADF PCB controller is damaged. The reader controller PCB isfaulty. OfDetection0001 Communication mode does not proceed in 3 seconds after the data has been writtento error register of IC communication (IPC) of the PCB ADFcontroller. 0002 bit transmission is not activated after a period of 10 seconds in thesync list of IPC(IC5021) on the reader controller PCB.B
The main cause of the connector is not connected properly. Finisher gear powersupply PCB damaged. Finisher controller PCB is damaged. The controllerPCB DC faulty.OfDetection0000 IC-mode communication (IPC) on the controller finisher have goneout order.E717
The main cause of the cable is faulty (short circuit, open circuit). Data copy of remote-control diagnostic orthe damaged. The main controller PCB faulty. OfDetection0001 The mode of copying the data controller or the controller circuit is damaged or anopen NE has been detected. Caution Fault must be reset in service mode (COPIER> > FUNCTION CLEAR ERR >).E719
The main cause of the cable is faulty (short circuit, open circuit). Faulty coin vendor.The main controller PCB faulty. Mode of Detection0001 communication between the vendor and the main controllerPCB coins had been interrupted. Caution Fault must be reset in service mode (COPIER > > FUNCTION CLEAR ERR >).E732
The main cause of this connector has poor contact. The reader controller PCB faulty.OfDetection0001 mode the main controller PCB has detected an error in the communicationbetween controller PCB and the main controllerPCB readers.E733
The main cause of this connector has poor contact. The DC Controller PCB faulty. OfDetection0001 mode the main controller PCB has detected an error in the communicationbetween the DC controller PCB and the main controller PCB. CLEAR > ERR). Printer Board (accessories) and the main controller PCB.E740
The main causes of LAN card is damaged. The main controller PCB faulty. Fashion ofDetection0001 error is detected on a LAN card at power-on (with cardinserted) 0.0002 A MAC address found faulty. 0003 LAN card register cannot be read.E741
The main cause of the PCI bus connection is not right. The main controller PCB faulty. Fashion ofDetection0000 an error has occurred on the PCI bus.E742
The main cause of RIP1 Board (accessory) is damaged. The main controller PCB faulty. Fashion ofDetection0000 Error has been detected by the self diagnosis of RIPI.E743
The main cause of this connector has poor contact. The main controller PCB faulty.Mode 0000 Detection controller PCB Readers have detected errors in the main controller PCB and communicationbetween controllerPCB readers.E804
The main cause of the cable is faulty (short circuit, open circuit). DC power supply fan (FM6) is damaged. The DC Controller PCB faulty. OfDetection0000 mode While the supply of DC power driven fan, clock signal (FM6CLK) don't come for 5 seconds or more.E805
The main cause of the cable is faulty (short circuit, open circuit). Fan feed (FM1) isfaulty. Heat dissipation fan (FM3) is damaged. The DC Controller PCB isfaulty. OfDetection0001 mode While a fan driven heat dissipation, signals clock (FM3CLK) don't come for 5 seconds or more. 0002 While fan-driven feed, signals clock (FM1CLK) don't come for 5 seconds or more.E824
The main cause of the cable is faulty (short circuit, open circuit). Main charging assemblycooling fan (FM2) is damaged. The DC Controller PCB faulty. OfDetection0000mode While charging the main cooling fan Assembly that is driven,E412
The main causes of cooling fan (FM1) is damaged. ADF controller PCB faulty. OfDetection0001 mode While the cooling fan is driven, key signal (FMLCK) arrived to 100msec or longer.E420
The main cause of the corrupted EEPROM. ADF controller PCB faulty. Detection mode of 0001 When the power button is turned on, the host machine backupdata fromEEPROM unreadable or the data, if read, has an error.E421
The main cause of the corrupted EEPROM. ADF controller PCB faulty. Mode ofDetection0001 Backup data cannot be written to the EEPROM data or, if a clock signal is written, URerror.the (FM2CLK) don't come for 5 seconds or more.E422
The main causes of communication IPC has errors. The lines of communication havean opencircuit. ADF controller PCB faulty. OfDetection0001 mode while the machineis in standby, communication with the hostmachine has been plagued for 5 secondsor more. or, while machineis in operations, communications with the host machine hasbeen disturbed during 0.5 seconds or more.E500
The main causes of faulty controller PCB finisher. The DC Controller PCB faulty. OfDetection0001 modes of communication between the host machine and hasbeen finisher disconnected; This error is detected by the host machine.E503
The main cause of saddle stitcher PCB controller is damaged. Finisher isfaulty controller PCB. OfDetection0002 mode of communication between saddle stitcher controller PCBand controller PCB has been plagued finisher.E504
The main causes of the high Sensor (PS1) is damaged. Finisher controller PCB faulty.OfDetection0001 modes of communication between the sensor and the altitude controllerPCB finisher is not possible, or communications data has errors. 0002 communications between sensors and elevation controllerPCB finisher is not possible for a certain period of time. 0003 upon power-on, the connector from the sensor height found tobe disconnected. 0004 When height sensors are adjusted by using the DIP switches, anerror occurs during adjustment.